How to exhaust the wall-mounted furnace radiator
As winter approaches, the frequency of use of wall-hung boilers and radiators gradually increases. However, many users encounter the problem that the radiator is not hot or makes too much noise during use. This is often due to the accumulation of air inside the radiator. This article will introduce in detail the steps and precautions for exhausting the wall-mounted boiler radiator to help you easily solve this problem.
1. Why is exhaust needed?

The accumulated air inside the radiator will affect the circulation of hot water, causing the radiator to be partially or overall not hot. In addition, the presence of air will generate noise and affect living comfort. Therefore, regular exhausting is an important step to ensure efficient operation of the radiator.
2. Preparations before exhausting
| Tools/Materials | Purpose |
|---|---|
| screwdriver | For unscrewing the exhaust valve |
| towel or container | catch drained water |
| gloves | Prevent burns |
3. Exhaust steps
| steps | Operating Instructions |
|---|---|
| 1. Turn off the boiler | Make sure the wall-mounted boiler is turned off to avoid hot water splashing when exhausting |
| 2. Find the exhaust valve | Usually located on the top or side of the radiator, is a small screw hole |
| 3. Unscrew the exhaust valve | Use a screwdriver to loosen the exhaust valve counterclockwise until you hear a "hissing" sound from the exhaust. |
| 4. Wait for exhaust to complete | When the exhaust sound disappears and water flows out, it means that the air has been exhausted |
| 5. Tighten the exhaust valve | Use a screwdriver to tighten the exhaust valve clockwise to ensure it does not leak. |
| 6. Check the radiator | Restart the wall-mounted boiler and observe whether the radiator heats evenly |
4. Precautions
1.Safety first: The water temperature may be high during exhaust. Be sure to wear gloves and use a towel to catch the water to avoid burns.
2.Avoid over-tightening: The exhaust valve only needs to be loosened a little. Excessive loosening may cause damage to the valve.
3.Regular inspection: It is recommended to exhaust air once before the start of each heating season to ensure efficient operation of the system.
4.Professional help: If the problem is not solved after exhausting, it may be due to other system faults. It is recommended to contact a professional for repair.
5. Frequently Asked Questions
| question | Solution |
|---|---|
| Exhaust valve leaking | Check whether the valve is tight and replace the seal if necessary |
| Radiator is still not hot after exhausting air | It may be that the pipe is blocked or the pressure of the wall-hung boiler is insufficient. Further inspection is required. |
| Exhaust valve cannot be opened | Do not force the operation, contact professionals to handle it |
6. Summary
Venting a wall-hung boiler radiator is a simple but important maintenance step that can effectively improve heating efficiency and reduce noise. With the detailed guidance in this article, you can easily complete the exhaust operation. If you encounter complex problems, please seek professional help in time to ensure the safe operation of the system.
I hope this article can help you solve your radiator exhaust problem and enjoy a warm and comfortable winter!